Uncover the future of SPARC Emulation with Charon SSP.
Download DatasheetStromasys is now SOC 2 Compliant
SOC2
Short answer: an HP-UX application built for PA-RISC can’t run directly on x86 or Linux, because x86 processors can’t execute PA-RISC instructions, and HP-UX has never been released for x86. There are three ways around it. You can port the application to Linux. You can keep it on HP hardware: your current HP 9000 servers, or Itanium-based Integrity servers, which are also end of life. Or you can emulate PA-RISC hardware on an x86 server, so that HP-UX and the application run unchanged. The free QEMU emulator runs 32-bit HP-UX up to 11i v1 on an emulated workstation and is useful for testing. For production, Stromasys Charon-PAR runs HP-UX 9.05 through 11i v3, and MPE/iX, on x86-64 Linux hosts, on premises or in the cloud.
Stromasys makes Charon-PAR, one of the options below. This page covers all of them, including the ones that don’t involve us.
Run these on the HP-UX system:
uname - a # release (B.10.20 to B.11.31) and machine type
model # system model, for example 9000/800/rp3440
getconf CPU_VERSION # 528 = PA-RISC 1.1, 532 = PA-RISC 2.0, 768 = Itanium
getconf KERNEL_BITS # 32-bit or 64-bit kernel
file /path/to/binary # shows PA-RISC1.1, PA-RISC2.0 or ELF-64 (64-bit)
ioscan -fn # installed hardware, including interface cards
swlist -l product # installed software products
The release tells you the HP-UX version: B.11.11 is 11i v1, B.11.23 is 11i v2 and B.11.31 is 11i v3.
If uname – a shows ia64, you’re on an Itanium-based Integrity server, not PA-RISC. PA-RISC applications may be running there under HP’s Aries translator. Charon-PAR emulates PA-RISC, not Itanium, so most of this page doesn’t apply.
If it shows 9000/7xx or 9000/8xx, you’re on PA-RISC: 9000/7xx machines are workstations and 9000/8xx machines are servers. The processor and the kernel decide what an emulator has to reproduce:
If file reports PA-RISC 2.0 code, the application needs a PA-RISC 2.0 processor, and 64-bit (ELF-64) binaries need a 64-bit kernel.
| Route | What changes | What you need | Removes HP hardware? | Main risk |
|---|---|---|---|---|
| Port to Linux | Application recompiled or rewritten; operating system changes | Source code, build skills, Linux versions of third-party software, a full retest | Yes | Cost and time; HP-UX specific code and byte-order bugs |
| Move to HP-UX 11i v3 on Itanium | Application recompiled, or run under HP’s Aries translator | Integrity servers, whose Itanium processors are no longer made; for Aries, applications without their own drivers or kernel modules | No: PA-RISC is replaced by Itanium | Swaps one end-of-life platform for another |
| Keep current hardware under third-party maintenance | Nothing | Spare parts and HP-UX skills | No | Parts scarcity and failure risk; it only buys time |
| Emulate PA-RISC on x86 (QEMU or Charon-PAR) | Hardware only; HP-UX and the application stay as they are | Disk images of the original system, an x86-64 Linux host, your HP-UX licence | Yes | The emulator must support your model and HP-UX release; performance must be tested |
Whatever the route, check the operating system’s support status. HP took its last orders for PA-RISC HP 9000 systems at the end of 2008, and support for HP-UX on HP 9000 ended in March 2021. HPE’s standard support for HP-UX 11i v3, the last release, ended on 31 December 2025. HPE now lists it as “Mature Software Product Support without Sustaining Engineering” through at least 31 December 2028. Intel stopped shipping Itanium processors in 2021, so Integrity servers are end-of-life hardware too. Emulation replaces the hardware, not the operating system: HP-UX 11i v1 running in an emulator is still HP-UX 11i v1.
An emulator is a program that behaves like a PA-RISC computer. It presents a virtual PA-RISC processor, memory, disks, network interfaces and a console to the operating system. HP-UX boots on it as it would on real hardware, and applications run unchanged. The emulator itself runs as an ordinary process on an x86-64 host.
QEMU’s PA-RISC emulator, qemu-system-hppa, emulates four HP machines: the HP 9000 715/64 and Visualize B160L workstations (32-bit), and the Visualize C3700 workstation and A400 server (64-bit).
QEMU has community support only: no vendor, no service levels. It runs on Linux, macOS and Windows hosts.
Good for: learning, testing, and reading data from 32-bit HP-UX workstation installs. Not suited to: 64-bit HP-UX servers, HP-UX 11i v2 or v3, MPE/iX, or anything that needs a support contract.
Charon-PAR from Stromasys emulates 32-bit HP 9000 workstations, 64-bit HP 9000 servers and HP 3000 systems:
| Product | Emulated systems | Operating systems |
|---|---|---|
| Charon-PAR/PA9-32 | Model 720 and B132L workstations | Model 720: HP-UX 9.05 to 11.00. B132L: HP-UX 10.20 to 11i v1 |
| Charon-PAR/PA9-64 | rp34xx and rp44xx servers, such as the rp3440 and rp4440 | HP-UX 11i v1, 11i v2 and 11i v3 |
| Charon-PAR/PA3 | HP 3000 A400, A500 and N4000 | MPE/iX 7.5 |
| Qemu | Charon-PAR | |
|---|---|---|
| 32-bit workstations | B160L: HP-UX 10.20 to 11i v1; HP-UX 9 not yet | Model 720 and B132L: HP-UX 9.05 to 11i v1 |
| 64-bit servers | Not yet: only 32-bit HP-UX boots | rp34xx and rp44xx: HP-UX 11i v1 to v3 |
| MPE/iX | A goal for the A400 | MPE/iX 7.5 on A400, A500 and N4000 |
| Graphics | X11 and CDE on HP-UX 10.20; no OpenGL | No graphics console on the B132L |
| Host | Linux, macOS or Windows | x86-64 Linux: RHEL or Rocky Linux 8 to 10 |
| Support | Community | Commercial, with service levels |
| Cost | Free, open source | Commercial licence |
Keep your existing HP-UX workloads running on x86-64 servers or cloud infrastructure with zero code changes with Charon PAR.
No. HP-UX has never been released for x86; its last two platforms were PA-RISC and Itanium. To run HP-UX on an x86 server, you emulate PA-RISC hardware, and HP-UX runs on the emulated system unchanged.
Not natively. Linux on x86 can’t execute PA-RISC instructions or provide HP-UX’s system calls. Either port the application to Linux, or run a PA-RISC emulator on the Linux host with HP-UX inside it. Charon-PAR works that way: Linux is the host, and HP-UX and the application run unchanged on the virtual PA-RISC system. In 2017 HPE said it would let customers re-host HP-UX workloads in Linux containers on x86 servers, without saying how or when; we know of no such product being released.
There are four: port the application to Linux; move to HP-UX 11i v3 on Itanium, which is also end of life; keep the current hardware under third-party maintenance; or emulate PA-RISC on x86. For emulation, QEMU covers 32-bit HP-UX workstation installs for testing, and Charon-PAR covers production servers, including 64-bit HP-UX 11i v1 to v3.
Porting the application to Linux, moving to HP-UX 11i v3 on Itanium, or keeping the current hardware under third-party maintenance. Porting removes the dependency on HP-UX, but needs the source code and a full retest. The other two keep you on end-of-life hardware. The options table above compares all four routes.
Yes: QEMU’s PA-RISC emulator, qemu-system-hppa. It runs 32-bit HP-UX 10.20 to 11i v1 on an emulated B160L workstation, and it’s useful and free for testing, training and recovering data from workstation disks. It doesn’t suit most production systems today: 64-bit HP-UX doesn’t run yet, so HP-UX 11i v2 and v3 and the rp-series servers are out of reach, and there’s no vendor support.
The advantages: HP-UX and the application run unchanged, so there’s no porting project, and the ageing hardware goes. The system can then run on current x86 servers, in a virtual machine or in the cloud. The disadvantages: performance depends on the workload and the host, so test before committing. Devices the emulator doesn’t reproduce, such as special interface cards, need another solution. HP-UX stays at its current release and support status. And you still need a licence for HP-UX, as well as for the emulator.
No, though configuration changes may be recommended to optimize performance on the emulated platform. HP-UX and the application run unchanged. What changes is the hardware underneath: disks become image files or mapped storage, and network interfaces map to the host’s.
The Stromasys Research Team is a collective of experts specializing in researching and writing about legacy systems modernization, virtualization, and hardware emulation. With a combined experience of over 15 years, the team has researched, written, and published 200+ in-depth content pieces exploring how organizations across manufacturing, aerospace, finance, and public sector environments extend the life of mission-critical platforms while transitioning to modern infrastructure. Their work is informed by real-world customer deployments, input from engineering, and updated insights on what is latest in the world of legacy systems including SPARC, PA-RISC, VAX, Alpha and PDP environments.
The IT landscape is rapidly evolving, and businesses still running legacy hardware are facing numerous...
Read MoreDid you know that a 1990s-era processor design still flies on NASA/ESA Solar Orbiter? That’s...
Read MoreFun fact: The HP 9000 series reached its End of Life (EOL) on April 30,...
Read MoreDon't let your legacy systems slow you down! Contact us today and transform your legacy environment into a dynamic, agile platform for success.
Kickstart your journey towards a more efficient and streamlined business environment with just one click.