Resource Banner

How to run old HP-UX applications on x86 or Linux

Talk to an Expert

Share Article:

Table of Contents

    Article icon Article

    Short answer: an HP-UX application built for PA-RISC can’t run directly on x86 or Linux, because x86 processors can’t execute PA-RISC instructions, and HP-UX has never been released for x86. There are three ways around it. You can port the application to Linux. You can keep it on HP hardware: your current HP 9000 servers, or Itanium-based Integrity servers, which are also end of life. Or you can emulate PA-RISC hardware on an x86 server, so that HP-UX and the application run unchanged. The free QEMU emulator runs 32-bit HP-UX up to 11i v1 on an emulated workstation and is useful for testing. For production, Stromasys Charon-PAR runs HP-UX 9.05 through 11i v3, and MPE/iX, on x86-64 Linux hosts, on premises or in the cloud.

    Stromasys makes Charon-PAR, one of the options below. This page covers all of them, including the ones that don’t involve us.

    Start by checking what you run

    Run these on the HP-UX system:

        
         uname - a                 # release (B.10.20 to B.11.31) and machine type
    model                     # system model, for example 9000/800/rp3440
    getconf CPU_VERSION       # 528 = PA-RISC 1.1, 532 = PA-RISC 2.0, 768 = Itanium
    getconf KERNEL_BITS       # 32-bit or 64-bit kernel
    file /path/to/binary      # shows PA-RISC1.1, PA-RISC2.0 or ELF-64 (64-bit)
    ioscan -fn                # installed hardware, including interface cards
    swlist -l product         # installed software products
    
        
       

    The release tells you the HP-UX version: B.11.11 is 11i v1, B.11.23 is 11i v2 and B.11.31 is 11i v3.

    If uname – a shows ia64, you’re on an Itanium-based Integrity server, not PA-RISC. PA-RISC applications may be running there under HP’s Aries translator. Charon-PAR emulates PA-RISC, not Itanium, so most of this page doesn’t apply.

    If it shows 9000/7xx or 9000/8xx, you’re on PA-RISC: 9000/7xx machines are workstations and 9000/8xx machines are servers. The processor and the kernel decide what an emulator has to reproduce:

    • 32-bit PA-RISC 1.1 systems: older workstations such as the Model 720, B132L and B160L, running HP-UX 9.x to 11i v1.
    • 64-bit PA-RISC 2.0 systems: later workstations and servers, such as the C3700 workstation and the rp2400, rp3440 and rp4440 servers, running HP-UX 11.00 to 11i v3.

    If file reports PA-RISC 2.0 code, the application needs a PA-RISC 2.0 processor, and 64-bit (ELF-64) binaries need a 64-bit kernel.

    Why an HP-UX application won’t run on x86 or Linux

    • Different instruction sets. A compiled HP-UX application is machine code for PA-RISC processors, and x86 processors can’t execute it.
    • HP-UX has never been released for x86. Its last two platforms were PA-RISC and Itanium. Unlike Solaris, there’s no x86 edition of the operating system to recompile for.
    • Linux is a different operating system. System calls, libraries, compilers and administration tools differ from HP-UX, so moving to Linux means recompiling and adapting the code.
    • Byte order. PA-RISC is big-endian and x86 is little-endian. Code that assumes big-endian order, which is common in binary file handling and network code, works on PA-RISC and breaks on x86. These bugs tend to surface late, in testing.
    RouteWhat changesWhat you needRemoves HP hardware?Main risk
    Port to LinuxApplication recompiled or rewritten; operating system changesSource code, build skills, Linux versions of third-party software, a full retestYesCost and time; HP-UX specific code and byte-order bugs
    Move to HP-UX 11i v3 on ItaniumApplication recompiled, or run under HP’s Aries translatorIntegrity servers, whose Itanium processors are no longer made; for Aries, applications without their own drivers or kernel modulesNo: PA-RISC is replaced by ItaniumSwaps one end-of-life platform for another
    Keep current hardware under third-party maintenanceNothingSpare parts and HP-UX skillsNoParts scarcity and failure risk; it only buys time
    Emulate PA-RISC on x86 (QEMU or Charon-PAR)Hardware only; HP-UX and the application stay as they areDisk images of the original system, an x86-64 Linux host, your HP-UX licenceYesThe emulator must support your model and HP-UX release; performance must be tested

    Whatever the route, check the operating system’s support status. HP took its last orders for PA-RISC HP 9000 systems at the end of 2008, and support for HP-UX on HP 9000 ended in March 2021. HPE’s standard support for HP-UX 11i v3, the last release, ended on 31 December 2025. HPE now lists it as “Mature Software Product Support without Sustaining Engineering” through at least 31 December 2028. Intel stopped shipping Itanium processors in 2021, so Integrity servers are end-of-life hardware too. Emulation replaces the hardware, not the operating system: HP-UX 11i v1 running in an emulator is still HP-UX 11i v1.

    How PA-RISC emulation works

    An emulator is a program that behaves like a PA-RISC computer. It presents a virtual PA-RISC processor, memory, disks, network interfaces and a console to the operating system. HP-UX boots on it as it would on real hardware, and applications run unchanged. The emulator itself runs as an ordinary process on an x86-64 host.

    QEMU: free, open source

    QEMU’s PA-RISC emulator, qemu-system-hppa, emulates four HP machines: the HP 9000 715/64 and Visualize B160L workstations (32-bit), and the Visualize C3700 workstation and A400 server (64-bit).

    • 32-bit HP-UX works. The B160L is the best-supported machine: HP-UX 10.20 to 11i v1 boot and install, with X11 and CDE on 10.20. HP-UX 11i v1 runs in 32-bit mode, so software built for PA-RISC 2.0 doesn’t run, and there’s no OpenGL. HP-UX 9 doesn’t install from CD with QEMU 11.1; patches that make it work are being added to QEMU.
    • 64-bit HP-UX doesn’t run yet. As of 2026, only 32-bit HP-UX boots, and the C3700 and A400 are still described as unstable. QEMU supports HP-UX install media up to 11i v1, so HP-UX 11i v2 and v3 are out of reach. Developers are working on 64-bit support, and aim to run MPE/iX on the A400.

    QEMU has community support only: no vendor, no service levels. It runs on Linux, macOS and Windows hosts.

    Good for: learning, testing, and reading data from 32-bit HP-UX workstation installs. Not suited to: 64-bit HP-UX servers, HP-UX 11i v2 or v3, MPE/iX, or anything that needs a support contract.

    Charon-PAR: commercial, built for production

    Charon-PAR from Stromasys emulates 32-bit HP 9000 workstations, 64-bit HP 9000 servers and HP 3000 systems:

    ProductEmulated systemsOperating systems
    Charon-PAR/PA9-32Model 720 and B132L workstationsModel 720: HP-UX 9.05 to 11.00. B132L: HP-UX 10.20 to 11i v1
    Charon-PAR/PA9-64rp34xx and rp44xx servers, such as the rp3440 and rp4440HP-UX 11i v1, 11i v2 and 11i v3
    Charon-PAR/PA3HP 3000 A400, A500 and N4000MPE/iX 7.5
    • Compatibility: runs unmodified copies of HP-UX and MPE/iX. Emulated SCSI disks and tapes map to image files or physical devices on the host, and network interfaces map to the host’s.
    • Capacity: up to 8 CPUs and 128 GB of memory on emulated rp44xx servers
    • Host: x86-64 Linux, either Red Hat Enterprise Linux or Rocky Linux 8, 9 or 10, on a physical server or a virtual machine. It runs on premises or in the cloud; AWS Marketplace lists it as “Virtual PA-RISC with VE licensing”; The AWS listing asks for an x86-64 processor of 3 GHz or faster, and 4 GB of RAM plus 1.5 times the emulated memory. Charon-PAR 4.0 includes a sizing script, charon-par-sizer.py.
    • Performance: Charon-PAR 4.0 adds DIT2, a second tier of dynamic instruction translation, which can run on the emulator’s host or on a separate server shared by several Charon-PAR instances. It speeds up some workloads more than others, so test your own before committing.
    • Limits to check: emulated SCSI disks are limited to 2 TB each, and the B132L runs without a graphics console. Graphical adapter is in development and is available on demand.
    • Licensing: a Stromasys Charon-PAR licence. You supply the HP-UX licence.
    • Support: commercial support from Stromasys with defined service levels.
      Good for: production HP-UX on 64-bit PA-RISC servers, HP-UX 11i v1 to v3, MPE/iX on HP 3000 systems, and datacenter exits to the cloud.
     QemuCharon-PAR
    32-bit workstationsB160L: HP-UX 10.20 to 11i v1; HP-UX 9 not yetModel 720 and B132L: HP-UX 9.05 to 11i v1
    64-bit serversNot yet: only 32-bit HP-UX bootsrp34xx and rp44xx: HP-UX 11i v1 to v3
    MPE/iXA goal for the A400MPE/iX 7.5 on A400, A500 and N4000
    GraphicsX11 and CDE on HP-UX 10.20; no OpenGLNo graphics console on the B132L
    HostLinux, macOS or Windowsx86-64 Linux: RHEL or Rocky Linux 8 to 10
    SupportCommunityCommercial, with service levels
    CostFree, open sourceCommercial licence

    What a move to Charon-PAR involves

    1. Collect system information and workload data using the Stromasys data collector for HP-UX.
    2. Size the host with charon-par-sizer.py, install Charon-PAR on an x86-64 Linux host, and configure a virtual system of a supported model.
    3. Migrate HP-UX and data. This step requires HP-UX expertise; common methods are an Ignite-UX recovery archive or copies of the original disks. Stromasys can provide migration automation tools, which speed up the process and reduce the HP-UX knowledge required.
    4. Boot HP-UX on the virtual system, adjust device and network settings, and test the application.
    5. Cut over.

    Which route fits

    • You have the source code, the team, and a reason to change the application anyway: port it to Linux.
    • The vendor is gone, the source is lost, or the system is certified as it stands: emulate. For production, use Charon-PAR.
    • You only need to run or examine a 32-bit HP-UX workstation install, for testing or to recover data: QEMU may be enough.
    • You need to leave the datacenter: port, or emulate on x86 servers or in the cloud. Moving to Itanium doesn’t get you off end-of-life hardware.
    • You’re already on Itanium-based Integrity servers: this page doesn’t apply, because Charon-PAR emulates PA-RISC, not Itanium.

    When emulation is the wrong choice

    • The application depends on hardware an emulator doesn’t reproduce, such as HP-IB instrument interfaces or custom PCI cards.
    • The application will be retired soon. Keeping the current hardware running until then may cost less.
    Stromasys Logo Horizontal

    Keep your existing HP-UX workloads running on x86-64 servers or cloud infrastructure with zero code changes with Charon PAR.

    tri3

    Frequently Asked Questions

    No. HP-UX has never been released for x86; its last two platforms were PA-RISC and Itanium. To run HP-UX on an x86 server, you emulate PA-RISC hardware, and HP-UX runs on the emulated system unchanged.

    About Author

    Stromasys Research Team

    Stromasys Research Team

    The Stromasys Research Team is a collective of experts specializing in researching and writing about legacy systems modernization, virtualization, and hardware emulation. With a combined experience of over 15 years, the team has researched, written, and published 200+ in-depth content pieces exploring how organizations across manufacturing, aerospace, finance, and public sector environments extend the life of mission-critical platforms while transitioning to modern infrastructure. Their work is informed by real-world customer deployments, input from engineering, and updated insights on what is latest in the world of legacy systems including SPARC, PA-RISC, VAX, Alpha and PDP environments.